THP3-7222

TRACO ELECTRONIC AG

THP3-7222
 
THP3-7222

THP3-7222

Availability
Available
Availability
Design risk
Medium
Design risk
Price trend
Stable
Price trend
Lead time
Stable
Lead time
15 results found
INA2143UA
Available
Available
Low
Low
Decreasing
Decreasing
Stable
Stable
AOSP21313C
Available
Available
High
High
Decreasing
Decreasing
Stable
Stable
PTN78000WAZT
Constrained
Constrained
Low
Low
Increasing
Increasing
Stable
Stable
WR04X3482FTL
Unavailable
Unavailable
Low
Low
Decreasing
Decreasing
Decreasing
Decreasing
HD3SS215IRTQR
Unavailable
Unavailable
Low
Low
Decreasing
Decreasing
Stable
Stable
SUP60020E-GE3
Available
Available
Low
Low
Decreasing
Decreasing
Increasing
Increasing
0402B223K160CT
Constrained
Constrained
Low
Low
Decreasing
Decreasing
Decreasing
Decreasing
0805B682K500CT
Constrained
Constrained
Low
Low
Decreasing
Decreasing
Decreasing
Decreasing
CL31X226KAHN3NE
Available
Available
Low
Low
Decreasing
Decreasing
Decreasing
Decreasing
MSP430F1232IPWR
Constrained
Constrained
Low
Low
Increasing
Increasing
Stable
Stable
NRF52810-QCAA-R
Available
Available
High
High
Increasing
Increasing
Decreasing
Decreasing
ADG451BRUZ-REEL...
Constrained
Constrained
Medium
Medium
Increasing
Increasing
Increasing
Increasing
AS7C34096A-10TC...
Unavailable
Unavailable
Low
Low
Decreasing
Decreasing
Stable
Stable
DF50-30DP-1H(51...
Available
Available
Low
Low
Increasing
Increasing
Stable
Stable
MX25L3233FM2I-0...
Available
Available
High
High
Decreasing
Decreasing
Increasing
Increasing

Semiconductors

Other Semiconductors

Lead Time     12 weeks
Data Sheet     Download THP3-7222 datasheet THP3-7222

DC converters, type Traco THP 3-. 3; .0 W converter with 4 : 1 input voltage range, DIL 24 package, reinforced insulation (for 300 VAC operating voltage, safety standards for the medical and industrial segments, input filter to EN 55022 class A, sustained short circuit-proof. MTBF: min. 1.0 million h at +25 °C. Adjustment tolerance: ±1.0 %. Input voltage fluctuation: ±0.5 %. Load fluctuation: ±1.0 %. Voltage balance at dual output: ±2.0 %. Residual ripple: 150 mVpp. Switching frequency: 150 kHz. Temperature coefficient: ±0.02 %/K typically. Operating temperatures: –40 to +85 °C. I/O insulation voltage: 4000 VAC. Insulation resistance: 1000 Mohm. Input voltage range from 36 to 160 VDC. Input current open-circuit/full load: 5.0/35 mA. Start voltage: 34 VDC. Low-voltage cut-out: 32 VDC. Recommended input fuse (time-lag): 0.3 A. Transient peaks (1.0 s): max. 180 VDC. Technical attributes (type, output voltage/current, typical efficiency): THP 3-7222, 2 x OUT, 12 VDC/0.125 A, 83 %

Technical Data

Manufacturer traco electronic ag
MPN THP3-7222
Technology HYBRID
Width (mm) 20.3000
Length (mm) 31.8000
JESD-30 Code R-PDMA-P24
Package Code DMA
Package Shape RECTANGULAR
Package Style ( Meter ) MICROELECTRONIC ASSEMBLY
Surface Mount NO
Terminal Form PIN/PEG
Number of Outputs 2.0000
Temperature Grade INDUSTRIAL
Terminal Position DUAL
Additional Feature ALSO HAS -12V ADDITIONAL OUTPUT
Number of Functions 1.0000
Number of Terminals 24.0000
Terminal Pitch (mm) 2.5400
Input Voltage-Max (V) 160.0000
Input Voltage-Min (V) 36.0000
Input Voltage-Nom (V) 72.0000
Package Body Material PLASTIC/EPOXY
Analog IC - Other Type DC-DC REGULATED POWER SUPPLY MODULE
Output Current-Max (A) 0.1250
Output Voltage-Max (V) 12.1200
Output Voltage-Min (V) 11.8800
Output Voltage-Nom (V) 12.0000
Seated Height-Max (mm) 11.0000
Trim/Adjustable Output ( V ) NO
Load Regulation-Max (%) 1.0000
Total Power Output-Max (W) 3.0000
Efficiency (Main Output) (%) 83.0000
Peak Reflow Temperature (Cel) NOT SPECIFIED
Operating Temperature-Max (Cel) 85.0000
Operating Temperature-Min (Cel) -40.0000
Time@Peak Reflow Temperature-Max (s) NOT SPECIFIED
Availability In stock

Submit Request

CONTACT REASON

Connect With Us

HEADQUARTERS

Sourceability North America, LLC

9715 Burnet Rd, Ste 200 Austin, TX 78758-5215

Frequently Asked Questions

As part of the category Semiconductors and subcategory Other Semiconductors, THP3-7222 optimizes energy distribution in electronic devices. Its DC converters, type Traco THP 3-. 3; .0 W converter with 4 : 1 input voltage range, DIL 24 package, reinforced insulation (for 300 VAC operating voltage, safety standards for the medical and industrial segments, input filter to EN 55022 class A, sustained short circuit-proof. MTBF: min. 1.0 million h at +25 °C. Adjustment tolerance: ±1.0 %. Input voltage fluctuation: ±0.5 %. Load fluctuation: ±1.0 %. Voltage balance at dual output: ±2.0 %. Residual ripple: 150 mVpp. Switching frequency: 150 kHz. Temperature coefficient: ±0.02 %/K typically. Operating temperatures: –40 to +85 °C. I/O insulation voltage: 4000 VAC. Insulation resistance: 1000 Mohm. Input voltage range from 36 to 160 VDC. Input current open-circuit/full load: 5.0/35 mA. Start voltage: 34 VDC. Low-voltage cut-out: 32 VDC. Recommended input fuse (time-lag): 0.3 A. Transient peaks (1.0 s): max. 180 VDC. Technical attributes (type, output voltage/current, typical efficiency): THP 3-7222, 2 x OUT, 12 VDC/0.125 A, 83 % allows minimizing losses and increasing the overall system efficiency.

As a component of the subcategory Other Semiconductors, THP3-7222 ensures stable output voltage even when the load changes. Its makes it a reliable element in multi-level power systems.

You can download the user manual and technical specifications for THP3-7222 in the documentation section.

DC converters, type Traco THP 3-. 3; .0 W converter with 4 : 1 input voltage range, DIL 24 package, reinforced insulation (for 300 VAC operating voltage, safety standards for the medical and industrial segments, input filter to EN 55022 class A, sustained short circuit-proof. MTBF: min. 1.0 million h at +25 °C. Adjustment tolerance: ±1.0 %. Input voltage fluctuation: ±0.5 %. Load fluctuation: ±1.0 %. Voltage balance at dual output: ±2.0 %. Residual ripple: 150 mVpp. Switching frequency: 150 kHz. Temperature coefficient: ±0.02 %/K typically. Operating temperatures: –40 to +85 °C. I/O insulation voltage: 4000 VAC. Insulation resistance: 1000 Mohm. Input voltage range from 36 to 160 VDC. Input current open-circuit/full load: 5.0/35 mA. Start voltage: 34 VDC. Low-voltage cut-out: 32 VDC. Recommended input fuse (time-lag): 0.3 A. Transient peaks (1.0 s): max. 180 VDC. Technical attributes (type, output voltage/current, typical efficiency): THP 3-7222, 2 x OUT, 12 VDC/0.125 A, 83 %